Air Grills

Air Grills

  • Specialised experience since 2001
  • Rated cubic feet per min airflow
  • Wind tunnel tested
  • Easy install and remove for maintenance and care
  • Optional fire flap for survey requirements manual or remotely activated
  • Any size and shape
  • Self draining
  • Versatile air ventilation protection for marine vessels and building industry eg.

    •  meter control rooms

    • powerhouse & generator room

Order online using our air grill order form

 

tech details

Air Intake test

Temperature 16 ° C
Pressure 1029 hPa
Air density 1.24 kg/m3
total cross section/filter cross section
  1.227
   
Downstream tunnel face Pressure Pressure
Pilot velocity velocity Drop Drop
(mmH2O) m/s m/s (mmH2O) Pa
1.63 5.08 6.23 12.2 119.32
2.67 6.50 7.98 18.2 178.00
4.33 8.28 10.16 29.8 291.46
7.27 10.73 13.16 49 479.24
10.33 12.78 15.69 71.3 697.34
14.40 15.09 18.52 97 948.70
18.13 16.94 20.78 123 1202.99
22.00 18.66 22.89 147 1437.72
website design & hosting justpurple